Tawanda, H. (2018). A Thermo-Economic Model for Aiding Solar Collector Choice and Optimal Sizing for a Solar Water Heating System: 23–26 January 2018, National University of Lesotho On occasion of NULISTICE 2018. Doi:10.1007/978-3-319-93438-9_1.
The choice of solar collector type to employ and the number of chosen collectors to subsequently deploy, are important planning decisions, which can greatly influence the economic attractiveness of solar water heating systems. In this paper, a thermo-economic model is developed for the computation of a suitable metric that can aid in choosing the most cost-effective collector to use in a solar water heating system and to determine the optimal sizing of the solar water heater components once the choice collector has been picked. The energy-per-dollar comparison metric, calculated as the annual heat energy output of the collector in an average year, at the so-called “sweet-spot” size of the collector array, divided by the annualized life-cycle cost, based on warranty life and collector initial cost, was recommended as instructive for comparing cost-effectiveness of different solar collectors. For the determination of the sweet-spot size of collector to use in a particular solar water heating system, at which the energy-per-dollar is calculated, the Net Present Value of Solar Savings was used as the objective function to maximize. Ten (10) different models of liquid solar thermal collectors (5 flat plate and 5 evacuated tube type), which are rated by the Solar Ratings & Certification Corporation (SRCC), were ranked according to the energy-per-dollar criterion through the thermo-economic model described in this study. At the sweet-spot collector area for the solar water heating system, the corresponding volume of hot water storage tank and the optimal solar fraction are also simultaneously determined. The required hot water storage volume decreases as the deployed collector area increases while the solar fraction increases, with diminishing marginal increase, until it saturates at a value of unity. For the present case study where the required load temperature is 50 °C and the solar water heating system is located in central Zimbabwe (latitude 19° S and longitude 30° E), the selected collector model happened to be a flat-plate type, which achieved the highest energy-per-dollar score of 26.1 kWh/$. The optimal size of this collector model to deploy in the solar water heating system at the case-study location is 18 m2 per m3 of daily hot water demand; with a hot water storage volume of 900 l/m3; at an optimal solar fraction of 91%. Although the method of this paper was applied only for a solar water heating application of specified operating temperature, at a specified location, it can be applied equally well for any other solar water heating application and at any other location.